The MCPs will only trip under a loss of power conditions [ ]. Trip logic is set for both manual and a loss of power condition for each individual pump.
104 The LHS MCP will trip when time > 1.e6 s (e.g., never active)?
CARD 206CCCC0, EXPANDED VARIABLE TRIP CARD
Card 20601040
W1(A) VARIABLE CODE = time
W2(I) PARAMETER = 0
W1(A) and W2(I) represent the current transient time
W3(A) RELATIONSHIP = gt
W4(A) VARIABLE CODE = null
W5(I) PARAMETER = 0
No comparison value is entered for the second variable
W6(R) ADDITIVE CONSTANT = 1.e6
This is an arbitrarily large user-specified time.
W7(A) LATCH INDICATOR = l
W8(R) TIMEOF QUANTITY (s) = It was set to either true (0.0) or false (-1.0) at the initiation of the transient
105 The RHS MCP 1 will trip when time > 1.e6 s (e.g., never active)?
CARD 206CCCC0, EXPANDED VARIABLE TRIP CARD
Card 20601050
W1(A) VARIABLE CODE = time
W2(I) PARAMETER = 0
W1(A) and W2(I) represent the current transient time
W3(A) RELATIONSHIP = gt
W4(A) VARIABLE CODE = null
W5(I) PARAMETER = 0
No comparison value is entered for the second variable
W6(R) ADDITIVE CONSTANT = 1.e6
This is an arbitrarily large user-specified time.
W7(A) LATCH INDICATOR = l
W8(R) TIMEOF QUANTITY (s) = It was set to either true (0.0) or false (-1.0) at the initiation of the transient
106 The RHS MCP 2 will trip when time > 1.e6 s (e.g., never active)?
CARD 206CCCC0, EXPANDED VARIABLE TRIP CARD
Card 20601060
W1(A) VARIABLE CODE = time
W2(I) PARAMETER = 0
W1(A) and W2(I) represent the current transient time
W3(A) RELATIONSHIP = gt
W4(A) VARIABLE CODE = null
W5(I) PARAMETER = 0
No comparison value is entered for the second variable
W6(R) ADDITIVE CONSTANT = 1.e6
This is an arbitrarily large user-specified time.
W7(A) LATCH INDICATOR = l
W8(R) TIMEOF QUANTITY (s) = It was set to either true (0.0) or false (-1.0) at the initiation of the transient
107 The RHS MCP 3 will trip when time > 1.e6 s (e.g., never active)?
CARD 206CCCC0, EXPANDED VARIABLE TRIP CARD
Card 20601070
W1(A) VARIABLE CODE = time
W2(I) PARAMETER = 0
W1(A) and W2(I) represent the current transient time
W3(A) RELATIONSHIP = gt
W4(A) VARIABLE CODE = null
W5(I) PARAMETER = 0
No comparison value is entered for the second variable
W6(R) ADDITIVE CONSTANT = 1.e6
This is an arbitrarily large user-specified time.
W7(A) LATCH INDICATOR = l
W8(R) TIMEOF QUANTITY (s) = It was set to either true (0.0) or false (-1.0) at the initiation of the transient
1104 Trip Signal for LHS MCP (Manual signal or loss-of-offsite power)
CARD 206CCCC0, EXPANDED LOGICAL TRIP CARD
Card 20611040
W1(I) TRIP NUMBER = 104
LHS MCP manual trip signal
W2(A) OPERATOR = or
W3(I) TRIP NUMBER = 102
Loss of offsite signal
W4(A) LATCH INDICATOR = n
W5(R) TIMEOF QUANTITY (s) = It was set to either true (0.0) or false (-1.0) at the initiation of the transient
1105 Trip Signal for RHS MCP 1 (Manual signal or loss-of-offsite power)
CARD 206CCCC0, EXPANDED LOGICAL TRIP CARD
Card 20611050
W1(I) TRIP NUMBER = 105
RHS 1 MCP manual trip signal
W2(A) OPERATOR = or
W3(I) TRIP NUMBER = 102
Loss of offsite signal
W4(A) LATCH INDICATOR = n
W5(R) TIMEOF QUANTITY (s) = It was set to either true (0.0) or false (-1.0) at the initiation of the transient
1106 Trip Signal for RHS MCP 2 (Manual signal or loss-of-offsite power)
CARD 206CCCC0, EXPANDED LOGICAL TRIP CARD
Card 20611060
W1(I) TRIP NUMBER = 106
RHS 2 MCP manual trip signal
W2(A) OPERATOR = or
W3(I) TRIP NUMBER = 102
Loss of offsite signal
W4(A) LATCH INDICATOR = n
W5(R) TIMEOF QUANTITY (s) = It was set to either true (0.0) or false (-1.0) at the initiation of the transient
1107 Trip Signal for RHS MCP 3 (Manual signal or loss-of-offsite power)
CARD 206CCCC0, EXPANDED LOGICAL TRIP CARD
Card 20611070
W1(I) TRIP NUMBER = 107
RHS 3 MCP manual trip signal
W2(A) OPERATOR = or
W3(I) TRIP NUMBER = 102
Loss of offsite signal
W4(A) LATCH INDICATOR = n
W5(R) TIMEOF QUANTITY (s) = It was set to either true (0.0) or false (-1.0) at the initiation of the transient